Multi frequency phase fluorimetry (MFPF) for oxygen partial pressure measurement: ex vivo validation by polarographic clark-type electrode.

2013

BACKGROUND: Measurement of partial pressure of oxygen (PO2) at high temporal resolution remains a technological challenge. This study introduces a novel PO2 sensing technology based on Multi-Frequency Phase Fluorimetry (MFPF). The aim was to validate MFPF against polarographic Clark-type electrode (CTE) PO2 measurements. METHODOLOGY/PRINCIPAL FINDINGS: MFPF technology was first investigated in N = 8 anaesthetised pigs at FIO2 of 0.21, 0.4, 0.6, 0.8 and 1.0. At each FIO2 level, blood samples were withdrawn and PO2 was measured in vitro with MFPF using two FOXY-AL300 probes immediately followed by CTE measurement. Secondly, MFPF-PO2 readings were compared to CTE in an artificial circulatory s…

Drugs and DevicesAnatomy and PhysiologyMaterials scienceSwinePartial PressurePhase (waves)Analytical chemistrychemistry.chemical_elementlcsh:Medicine610 Medicine & healthBioengineeringCardiovascularCardiovascular SystemOxygenFluorescence spectroscopyMedical Devices03 medical and health sciencesEngineering0302 clinical medicineAnesthesiologyDiagnostic MedicineAnimalsFluorometryddc:610030212 general & internal medicine610 Medicine & healthlcsh:ScienceBiologyBlood gas analysisPolarographyChemical PhysicsAnesthesiology TechnologyMultidisciplinaryPhysicslcsh:RPartial pressureModels TheoreticalOxygenChemistrychemistryElectrodeMedicineHigh temporal resolutionlcsh:QBlood Gas Analysis030217 neurology & neurosurgeryResearch ArticlePLoS ONE
researchProduct

Assessment of regional ventilation distribution: comparison of vibration response imaging (VRI) with electrical impedance tomography (EIT)

2013

BACKGROUND: Vibration response imaging (VRI) is a bedside technology to monitor ventilation by detecting lung sound vibrations. It is currently unknown whether VRI is able to accurately monitor the local distribution of ventilation within the lungs. We therefore compared VRI to electrical impedance tomography (EIT), an established technique used for the assessment of regional ventilation. METHODOLOGY/PRINCIPAL FINDINGS: Simultaneous EIT and VRI measurements were performed in the healthy and injured lungs (ALI; induced by saline lavage) at different PEEP levels (0, 5, 10, 15 mbar) in nine piglets. Vibration energy amplitude (VEA) by VRI, and amplitudes of relative impedance changes (rel.ΔZ) …

Diagnostic ImagingPathologymedicine.medical_specialtyAnatomy and PhysiologyCritical Care and Emergency MedicinePulmonologyVibration Response ImagingSwineRespiratory SystemLung soundlcsh:MedicineVibrationModel OrganismsRespiratory FailureAnesthesiologyBedside TechnologyElectric ImpedancemedicineMedical imagingAnimalsRespiratory Physiologyddc:610lcsh:ScienceTomographyBiologyElectrical impedance tomographyAnesthesiology MonitoringPhysicsAnalysis of VarianceModels StatisticalAnesthesiology TechnologyMultidisciplinarylcsh:RAnimal Modelsrespiratory systemrespiratory tract diseasesPulmonary imagingSpirometryBreathingMedicinelcsh:QTomographyPulmonary VentilationResearch ArticleBiomedical engineering